AOpen DE7200 Series Instruções de Operação Página 57

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 56
OPERATING INSTRUCTIONS
30 Sep 13 4-19
DE-7200VFDCentrifuge
By entering “User1” for user name and password “1-1-1-1” on the Login screen, the operating
range screen is displayed (Figure 4-18). The user may then set the maximum and minimum limits
for the following parameters:
Bowl speed
Conveyor differential speed
Pump GPM
Figure 4-18. Operating Range Screen
PUMP SETUP SCREEN
Pump parameters are input and viewed on the Pump Setup screen (Figure 4-19), which is
accessed from the Setup screen. Information keyed in from the pump and drive motor operating
specifications is used by the control system to calculate pump flow rate relative to motor speed
and autotune the pump motor to its controlling VFD. Accurate information for the specific pump in
use is critical for proper operation. Typically, a flow curve is required to obtain the pump output
per revolution parameter.
Figure 4-19. Pump Setup Screen
CLEAN OUT
The Clean Out screen (Figure 4-20) is used to set parameters for operating the bowl and/or
conveyor to remove accumulated process material that is impeding rotation. With this screen
displayed, the operator selects the desired bowl and conveyor RPMs for the cleanout process.
During cleanout, the actual RPMs and torque percentages are displayed below the setpoints.
Vista de página 56
1 2 ... 52 53 54 55 56 57 58 59 60 61 62 ... 166 167

Comentários a estes Manuais

Sem comentários